GminiP Series of micro-Pump Low power consumption, current, noise, anti-corrosive gases and ozone gas, and with two mounting holes. Analyzer for Pocket suction pump, gas sampling, medical instrument, beauty instrument and so on. Volume such as the thumb.

Name and model

Voltage

(V)

No-load Current

(mA)

Pressure

(kPa)

Vacum

(kPa)

Intake Flow

(mL/min)

Weight

(g)

Pump Size

Detailed Structure of the show

reference Appearance

GminiPA-1

3.5

30-50

35

-25

800

16

16×24×31

>>here

GminiPA-2

3.5

30-40

35

-20

300

16

16×24×31

>>here

Ibid

pressure unit conversion table

GminiP Series of micro-Pump Low power consumption, current, noise, anti-corrosive gases and ozone gas, and with two mounting holes. Analyzer for Pocket suction pump, gas sampling, medical instrument, beauty instrument and so on. Volume such as the thumb.

Name and model

Voltage

(V)

No-load Current

(mA)

Pressure

(kPa)

Vacum

(kPa)

Intake Flow

(mL/min)

Weight

(g)

Pump Size

Installation instructions

Detailed Structure of the show

reference Appearance

GminiPB-1

3.5

100

35

-25

800

28

16×24×41

>>here

GminiPB-2

3.5

100

35

-20

300

28

16×24×41

>>here

Ibid

GMPA Series of micro-Pump  the pump size is small, current, power consumption, low noise, stable and reliable, with mounting holes for the lithium battery-powered instrument for the pursuit of high-quality user ,With special needs can be put on a positive pressure above 0.1mpa (Suction pump for pocket analyzer, gas sampler, medical instrument, beauty instrument and so on.

Name and model

Voltage

(V)

No-load Current

(mA)

Pressure

(kPa)

Vacum

(kPa)

Intake Flow

(L/min)

Weight

(g)

Pump Size

Installation instructions

Structure of the show

reference Figure

GMPA-1

1.5-5

test:4V

≈40-100

50

20-30

0.3-1.5

35

40×23×36

flow-load diagram

voltage-flow chart

Structure>>here

GMPA-2

2.0-5

test:4V

≈30-100

50

30-40

0.5-2.0

35

40×23×36

Ibid

Ibid

GMPA-3

3-6

≈40-70

50

20-30

0.5-1.5

35

40×23×36

Ibid

Ibid

GMPA-4

3-6

≈50-90

50

30-40

0.5-1.8

35

40×23×36

Ibid

Ibid

 

GMPC Series of micro-pump   the pump size is small, low noise, small power consumption,stable and reliable hand-held devices used to pump suction. particularly suitable for demanding vacuum environments. with special needs can be put on a positive pressure above 0.1mpa .suction pumps for pocket gas sampler, medical instrument, beauty instrument, breast pump

Name and model

Voltage

(V)

No-load Current

(mA)

Pressure

(kPa)

Vacum

(kPa)

Intake Flow

(L/min)

Weight

(g)

Pump Size

Installation instructions

Structure of the show

reference Figure

GMPC-1/2/3

6/9/12

<200/120/90

>100

50-65

2.5-3

45

522×31

 

Structure>>here

flow-load diagram

voltage-flow chart

GMPC-4/5/6

6/9/12

<150/110/80

>80

50-55

2.0-2.5

45

522×31 ibid

ibid

GMPD Series of micro-pumpsuction pumps for pocket gas sampler, medical instrument, beauty instrument, breast pump with special needs can be put on a positive pressure above 0.1mpa .

Name and model

Voltage

(V)

No-load Current

(mA)

Pressure

(kPa)

Vacum

(kPa)

Intake Flow

(L/min)

Weight

(g)

Pump Size

Installation instructions

Structure of the show

reference Figure

GMPD-1/2/3

6/12/24

<230/130/80

60-100

60

3-8

82

35×44.5×56.5

flow-load diagram

voltage-flow chart

Structure>>here

GMPD-4/5/6

6/12/24

<200/100/60

60-100

50

3-7

82

35×44.5×56.5 ibid

ibid

                   

Custom products 6,9,12,24 volts, flow 2L, 3l, 4l can be customized, there are 20 models

GMPE Series of micro-pump To provide a special and long life motor, flow rate no less, suction pumps for pocket gas sampler, medical instrument, beauty instrument, breast pump

Name and model

Voltage

(V)

No-load Current

(mA)

Pressure

(kPa)

Vacum

(kPa)

Intake Flow

L/min

Weight(g)

Pump Size

Structure of the show

reference Figure

GMPE-1/2

12/24

<180/90

60

50-55

3-6

149

335×43.5×72

flow-load diagram

voltage-flow chart

Structure>>here

GMPE-3/4/-

12/24   -20-40 Custom 3L、4L、5L 149 35×43.5×72

Note: The custom products 2L, 3L, 4L can be customized, a total of 10 variety

GMPF Series of micro-pump   A single-channel pump, flow is very stable, suitable for a variety of gas sampling.

Name and model

Voltage

(V)

No-load Current

(A)

Pressure

(kPa)

Vacum

(kPa)

Intake Flow

L/min

Weight(g)

Pump Size

Structure of the show

reference Figure

GMPF25-1/2

12/24 0.6/.3 >100 -70 25 480 86×56.5×126

 

Structure>>here

GMPF15-3/4

12/24 0.6/0.3 >60 -50 18 480 86×56.5×126

Structure>>here

 

                   

GMPG Series of micro-pump A new single-channel pump, flow is very stable, suitable for a variety of gas sampling, changes in motor and voltage can produce six varieties.

Name and model

Voltage

(V)

No-load Current

(A)

Pressure

(kPa)

Vacum

(kPa)

Intake Flow

L/min

Weight(g)

Pump Size

Structure of the show

reference Figure

GMPG-1/2

6-12/24

<0.450

100

20-50

36

620

86×70×126

 

Structure>>here

GMPG-3/4

6-9/24

<0.550

100

20-50

36

620

86×70×126  

ibid

GDMPB Series Mini Double Pump        The pump can be due to double-headed pump gas path phase complementary mix to meet the requirements of constant-current sample, while a pump can replace the double-beat and sampling pump so that the system control circuit becomes simple, reducing circuit cost, function more flexible.

 

Name and model

Voltage

(V)

No-load Current

(A)

Pressure

(kPa)

Vacum

(kPa)

Intake Flow

L/min

Weight(g)

Pump Size

Structure of the show

reference Figure

GDMPB-1/2

6/12

<0.25/0.135

 

 

100

series260

 

-45-55

series vacum

 -85

single:2×2

dual:2.8

55

24×47×49

flow-load diagram

voltage-flow chart

Structure>>here

GDMPB-3/4

6/12 

<0.25/0.135

 

100

series260

50-65

single:2.5×2

dual:3.8

55

24×47×49

 

ibid

GDMPC Series Mini Double Pump   The pump can be due to double-headed pump gas path phase complementary mix to meet the requirements of constant-current sample, while a pump can replace the double-beat and sampling pump so that the system control circuit becomes simple, reducing circuit cost, function more flexible.

Name and model

Voltage

(V)

No-load Current

(A)

Pressure

(kPa)

Vacum

(kPa)

Intake Flow

L/min

Weight(g)

Pump Size

Structure of the show

reference Figure

GDMPC-1/2

12/24

<0.135/0.08

100

series260

-45-55

series vacum

-75

single

2×2L/min

dual

2.8L/min

75

24×47×51

flow-load diagram

voltage-flow chart

Structure>>here

GDMPC-3/4

12/24

<0.135/0.08

 

series

260

-50-65

series vacum

-80

single:2.5×2

dual:3.8

5

24×47×51  

ibid

 

GDMPD Series Mini Double Pump  The pump is designed to meet the user requirements of the design flow, high stability, due to double-headed pump gas path can be complementary and mixed phase can meet the requirements of constant-current sample, while a pump can replace the double-beat and sampling pump so that the system control circuit simple, to reduce circuit cost, function more flexible.

Name and model

Voltage

(V)

No-load Current

(mA)

Pressure

(kPa)

Vacum

(kPa)

Intake Flow

L/min

Weight(g)

Pump Size

Structure of the show

reference Figure

GDMPD-1/2

12/24

<200

/135

100

-40-50

series vacum

-75

single:7×2

dual:10

107

35×48×55.5  

GDMPD-3/4

12/24

<240

/135

100

-40-60

series vacum

-80

single:8×2

dual:11

107

35×48×55.5    

GDMPD-5/6

12/24

<180

/115

100

-35-45

single:5×2

dual:8

107

35×48×55.5    
                   

GDMPE Series Mini Double Pump The pump is designed to meet the user requirements of the design flow, high stability, due to double-headed pump gas path can be complementary and mixed phase can meet the requirements of constant-current sample, while a pump can replace the double-beat and sampling pump so that the system control circuit simple, to reduce circuit costs, function more flexible and longer motor life

Name and model

Voltage

(V)

No-load Current

(mA)

Pressure

(kPa)

Vacum

(kPa)

Intake Flow

L/min

Weight(g)

Pump Size

Structure of the show

reference Figure

GDMPE-1/2

12/24

<180/100

100

-40-50

series vacum

-75

single:6×2

dual:10

175

35×48×71.5

flow-load diagram

voltage-flow chart

Structure>>here

                   

GDMPF Series Mini Double Pump  Use of rare earth high-grade fully enclosed motor, flow stability, suitable for dust sampling, micro-organisms, a variety of gas sampling. gas line more stable.

Name and model

Voltage

(V)

No-load Current

(A)

Pressure

(kPa)

Vacum

(kPa)

Intake Flow

L/min

Weight(g)

Pump Size

Structure of the show

reference Figure

GDMPF(40)-1/2

12/24

≈0.80

100

20-60

single:28×2

dual:40

618

10×56.5×126

voltage-flow chart

Structure>>here

GDMPF(25)-3/4

12/24

 

≈0.70

100

20-60

single:20×2,

dual:25

663

10×56.5×126  

ibid

                   

GDMPG Series Mini Double Pumpuse of rare earth high-grade fully enclosed motor, flow stability, suitable for dust sampling, microbiological sampling, a variety of gas sampling, sampling of the double-headed just need a pump

Name and model

Voltage

(V)

No-load Current

(A)

Pressure

(kPa)

Vacum

(kPa)

Intake Flow

L/min

Weight(g)

Pump Size

Structure of the show

reference Figure

GDMPG(50)-1/2

6-12/24

<1.0

60

20-50

single:35×2

dual:50

759

110×70×126

 

Structure>>here

 

GDMPG(35)-3/4

6-12/24

<1.0

-50-60

20-50

single:25×2

dual:50

759

110×70×126

 

Structure>>here

 

 

                   

GFMPE Series of four-channel Pump Use of rare earth high-grade fully enclosed motor, flow stability, suitable for dust sampling, microbiological sampling, a variety of gas sampling, can be composed of a four-way mixed-constant pump, flow is very stable.

Name and model

Voltage

(V)

No-load Current

(A)

Pressure

(kPa)

Vacum

(kPa)

Intake Flow

L/min

Weight(g)

Pump Size

Structure of the show

reference Figure

GFMPE-1/2 12/24 <0.67/0.35 -- 60 Four:5-18 375 45×64.5×124

Structure>>here

GFMPE-3/4

12/24

<0.67/0.35.67 

--

45

Four:3-15

375 45×64.5×124    
Other         Four:1-10 375 45×64.5×124    
                   

HLA-2 Manual vacuum sampler series Test tube-specific, non-electric manual, negative pressure changes with the personal power

Name and model

Voltage

(V)

No-load Current

(mA)

Pressure

(kPa)

Vacum

(kPa)

Intake Flow

L/min

Weight(g)

Pump Size

Structure of the show

reference Figure

HLA-2

 

--

    50mL and 100mL two tranches.    

Help

Categories

  

                           Return Home Page