 micro-pump, vacuum-class -95, pressure 800kpa.
SSelect micro-pump
 

 GPMPA Series of DC micro-Pump oil-less Piston High-performance pump, you can load continuous operation, to overcome the shortcomings of the diaphragm pump can be used for gas sampling.)

Name and model

Voltage

(V)

No-load Current

(A)

Pressure

(kPa)

Vacum(kPa)

Intake Flow

(L/min)

Weight

(g)

Pump Size

Detailed Structure

Show

GPMPA-1/2

12/24

0.48/0.28

300-360

-75

4

214

35×52×80

Show

GPMPA-3/4 12/24

0.38/0.18

180 -58 3.5 210

35×52×80

  Ibid
GPMPA-5/6 12/24

0.38/0.18

110 -48 2.5 210

35×52×80

  Ibid

GPMPB Series of DC micro-pump oil-less Piston( High-performance pump, you can load continuous operation, to overcome the shortcomings of the diaphragm pump can be used for gas sampling.)

 

Name and model

Voltage

(V)

No-load Current

(A)

Pressure

(kPa)

Vacum(kPa)

Intake Flow

(L/min)

Weight

(g)

Pump Size

Detailed Structure

Show

 

GPMPB-1/2

12/24

0.48/0.25

230-200

65

5.5

212

35×52×80

Show

Ibid

GPMPB-3/4

12/24

0.48/0.25

230-200

65

5.5

212

35×52×80

  Ibid
GPMPB-5/6 12/24

0.48/0.25

140 50 3.5 212

35×52×80

  Ibid

GPMPCSeries of DC micro-pump oil-free piston( High-performance pump, you can load continuous operation, to overcome the shortcomings of the diaphragm pump can be used for gas sampling.)

Name and model

Voltage

(V)

No-load Current

(A)

Pressure

(kPa)

Vacum(kPa)

Intake Flow

(L/min)

Weight

(g)

Pump Size

Detailed Structure

Show

 

GPMPC-1/2

12/24

0.58/0.30

--

-80

11

214

35×52×80

Show

Ibid

GPMPC-3/4 12/24

0.58/0.30

-- -65 9

214

35×52×80

  Ibid

 

GPMPC-5/6 12/24 0.58/0.30 140 -60 6 214

35×52×80

  Ibid

GPMPD  Series of DC micro-pump oil-free piston---Pressure: 400kPa

High-performance pump that can run under load, to overcome the shortcomings of the diaphragm pump can be used to suppress the system.

Name and model

Voltage

(V)

No-load Current

(A)

Pressure

(kPa)

Vacum(kPa)

Intake Flow

(L/min)

Weight

(g)

Pump Size

Detailed Structure

Show

 

GPMPD-1/2

12/24

0.40/0.20

>300

-75

6

293

35×52×105

Show

GPMPD-3/4

12/24

0.38/0.20

>200

-60

4.5

293

35×52×105

  Ibid

GPMPD-5/6

12/24

0.38/0.18

>150

-50

3

293

35×52×105

  Ibid

GPMPE Series of DC micro-pump oil-free piston---Pressure: 500kPa

High-performance pump that can run under load, to overcome the shortcomings of the diaphragm pump can be used to suppress the system.

Name and model

Voltage

(V)

No-load Current

(A)

Pressure

(kPa)

Vacum(kPa)

Intake Flow

(L/min)

Weight

(g)

Pump Size

Detailed Structure

Show

 

GPMPE-1/2

12/24

0.38/0.20

>400

-80

8

293

35×52×105

Show

Ibid

GPMPE-3/4

12/24

0.38/0.20

>250

-60

5

293

35×52×105

Show

Ibid

GPMPE-5/6

 

12/24

0.38/0.18

>150

-50

3

293

35×52×105

Show

Ibid

GPMPE Series of DC micro-pump oil-free piston---Pressure: 500kPa

High-performance pump that can run under load, to overcome the shortcomings of the diaphragm pump can be used to suppress the system.

Name and model

Voltage

(V)

No-load Current

(A)

Pressure

(kPa)

Vacum(kPa)

Intake Flow

(L/min)

Weight

(g)

Pump Size

Detailed Structure

Show

 

GPMPF-1/2

12/24

0.40/0.20

--

-80

13

293

35×52×105

Show

Ibid

GPMPF-3/4

12/24

0.46/0.20

>200

-65

10

293

35×52×105

Show

Ibid

GPMPF-5/6

12/24

0.34/0.18

>150

-55

6

293

35×52×105

Show

Ibid

GPMPE Series of DC micro-pump oil-free piston---Pressure: 500kPa

High-performance pump that can run under load, to overcome the shortcomings of the diaphragm pump can be used to suppress the system.

Name and model

Voltage

(V)

No-load Current

(A)

Pressure

(kPa)

Vacum(kPa)

Intake Flow

(L/min)

Weight

(g)

Pump Size

Detailed Structure

Show

 

GPMPG-1/2

12/24

0.38/0.20

≈490

-80

7.0

483

40×58×120

Show

GPMPG-3/4

12/24

0.38/0.20

400-450

-75

5

483

40×58×120

Show

Ibid

                   

GPMPE Series of DC micro-pump oil-free piston---Pressure: 500kPa

High-performance pump that can run under load, to overcome the shortcomings of the diaphragm pump can be used to suppress the system.

Name and model

Voltage

(V)

No-load Current

(A)

Pressure

(kPa)

Vacum(kPa)

Intake Flow

(L/min)

Weight

(g)

Pump Size

Detailed Structure

Show

GPMPH-1/2

12/24

0.48/0.25

≈450

-78

10

483

40×58×120

Show

Ibid

GPMPH-3/4

12/24

0.48/0.25

400

-75

8

483

40×58×120

Show

Ibid

                   

GPMPE Series of DC micro-pump oil-free piston---Pressure: 500kPa

High-performance pump that can run under load, to overcome the shortcomings of the diaphragm pump can be used to suppress the system.

Name and model

Voltage

(V)

No-load Current

(A)

Pressure

(kPa)

Vacum(kPa)

Intake Flow

(L/min)

Weight

(g)

Pump Size

Detailed Structure

Show

GPMPI-1/2

12/24

0.48/0.25

>400

-80

15

483

40×58×120

Show

Ibid

 

GPMPI-3/4

12/24

0.48/0.25

380

-75

12

483

40×58×120

Show

Ibid

                   

GPMPE Series of DC micro-pump oil-free piston---Pressure: 500kPa

High-performance pump that can run under load, to overcome the shortcomings of the diaphragm pump can be used to suppress the system.

Name and model

Voltage

(V)

No-load Current

(A)

Pressure

(kPa)

Vacum(kPa)

Intake Flow

(L/min)

Weight

(g)

Pump Size

Detailed Structure

Show

GPMPJ-1/2 12/24 1.0/0.5 〉380 -80 25 650 58×95×144

Show

GPMPJ-1/2 12/24 1.0/0.5 〉260 -70 18 650 58×95×144

Show

Ibid

 
                 

Ibid

GDPMPA Series of DC micro-pump oil-free piston Vacum:-80 to -95kPa;Pressure:600kPa

High-performance pump that can run under load, to overcome the shortcomings of the diaphragm pump can be used to suppress the system.

Name and model

Voltage

(V)

No-load Current

(A)

Pressure

(kPa)

Vacum(kPa)

Intake Flow

(L/min)

Weight

(g)

Pump Size

Detailed Structure

Show

 

GDPMPA-1/2

12/24

0.48/0.20

-- -90 5, and:7

355

35×52×127

 

GDPMPA-3/4

12/24

0.48/0.20

600-700 -82 4.7,and:6

355

35×52×127

 

Ibid

 
Other parameters Customized       Customized  

35×52×127

 

Ibid

GDPMPA Series of DC micro-pump oil-free piston Vacum:-80 to -95kPa;Pressure:600kPa

High-performance pump that can run under load, to overcome the shortcomings of the diaphragm pump can be used to suppress the system.

Name and model

Voltage

(V)

No-load Current

(A)

Pressure

(kPa)

Vacum(kPa)

Intake Flow

(L/min)

Weight

(g)

Pump Size

Detailed Structure

Show

GDPMPB-1/2

12/24

0.85/0.50

-- -93 8,and:12

355

35×52×127

 

Ibid

 

GDPMPB-3/4

12/24

0.85/0.50

-- -89 7,and:10

355

35×52×127

 

Ibid

GDPMPB-5/6

12/24

  -- -80 5,and:8   35×52×127  

Ibid

 

GDPMPA Series of DC micro-pump oil-free piston Vacum:-80 to -95kPa;Pressure:600kPa

High-performance pump that can run under load, to overcome the shortcomings of the diaphragm pump can be used to suppress the system.

Name and model

Voltage

(V)

No-load Current

(A)

Pressure

(kPa)

Vacum(kPa)

Intake Flow

(L/min)

Weight

(g)

Pump Size

Detailed Structure

Show

GDPMPC-1/2

12/24

0.90/0.60

-- -93 13and:19

355

35×52×122

 

Ibid

 

GDPMPC-3/4

12/24

0.90/0.60

-- -85 11and:17

355

35×52×122

 

Ibid

GDPMPC-5/6

12/24

0.90/0.60 -- -70 9and:15

355

35×52×127  

Ibid

GDPMPD  Series of DC micro-pump oil-free piston Vacum:-80 to -95kPa;Pressure:800kPa

High-performance pump that can run under load, to overcome the shortcomings of the diaphragm pump can be used to suppress the system.

Name and model

Voltage

(V)

No-load Current

(A)

Pressure

(kPa)

Vacum(kPa)

Intake Flow

(L/min)

Weight

(g)

Pump Size

Detailed Structure

Show

GDPMPC-1/2

12/24

0.90/0.60

-- -93 13and:19

355

35×52×122

 

GDPMPC-3/4

12/24

0.90/0.60

-- -85 11and:17

355

35×52×122

 

Ibid

 
GDPMPC-5/6

12/24

0.90/0.60 -- -70 9and:15

355

35×52×127  

Ibid

GDPMPD  Series of DC micro-pump oil-free piston Vacum:-80 to -95kPa;Pressure:800kPa

High-performance pump that can run under load, to overcome the shortcomings of the diaphragm pump can be used to suppress the system.

Name and model

Voltage

(V)

Power

(W)

Pressure

(kPa)

 Vacum(kPa)

Intake Flow

(L/min)

Weight

(g)

Pump Size

Detailed Structure

Show

 

GDPMPE-1/2

12/24 1.0/0.6 -- -93 12and:16 565 40×58×157  

Ibid

 

GDPMPE-1/2

12/24 1.0/0.6 -- -82 8,and:12 565 40×58×157    

GDPMPD  Series of DC micro-pump oil-free piston Vacum:-80 to -95kPa;Pressure:800kPa.

High-performance pump that can run under load, to overcome the shortcomings of the diaphragm pump can be used to suppress the system.

Name and model

Voltage

(V)

No-load Current

(A)

Pressure

(kPa)

Vacum(kPa)

Intake Flow

(L/min)

Weight

(g)

Pump Size

Detailed Structure

Show

 

GDPMPF-1/2

12/24 1.0/0.6 -- -93 14,and:20 565 40×58×157  

Ibid

GDPMPF-1/2 12/24 1.0/0.6 -- -82 12,and:18 565 40×58×157  

Ibid

GPMPAC Series of AC micro-pump oil-free piston Vacum:-80 Pressure:800kPa.The need to provide users with high vacuum, the pump is portable and can plug directly into 220 power. Is a good helper for scientific research and laboratory

Name and model

Voltage

(V)

Power

(W)

Pressure

(kPa)

 Vacum(kPa)

Intake Flow

(L/min)

Weight

(g)

Pump Size

Detailed Structure

Show

 

GPMPAC

AC220

1/6

600

-80

23

2.4

200×135×170

 

                   
                   

GDPMPAC Series AC miniature oil-free piston pump --- vacuum:-80kPa need to provide users with high-voltage vacuum, the pump is portable, can be directly inserted 220 electricity. Is a good helper for research and laboratory

GDPMPAC

AC220

1/3

--

-80

35

5

320×135×170

 
                   
Categories